Standing Seam Metal Roofing in Staten Island, NY

Standing seam metal roofing for Staten Island schools, civic buildings and industrial sheds: clip systems, seam checks, trim and wind exposure.

A slab of snow that has slid off a standing seam roof and taken a stretch of gutter with it is the first thing an inspector writes up on a January walk, and the question that follows is where the next slab will land. The panels run in long straight lines with raised seams between them, and the field of a panel is almost never what leaks. The trouble is at the ends of the seams, at the eaves and at every pipe or curb that interrupts a run.

Commercial Roofing Staten Island inspects, repairs and installs standing seam metal roofs on the island, and we tell facility directors where the system fits and where a low-slope membrane is the better buy.

What standing seam is

Standing seam is a metal panel system with raised, interlocking seams that run from eave to ridge. Panels are held down by concealed clips under the seam rather than screws through the face, which lets each panel slide as the metal expands and contracts, and the seams are snapped together or folded mechanically on site, with the folded seam the more watertight of the two.

The concealed clips are the point. With no fasteners through the face there are fewer holes to leak, and thermal movement is absorbed by the clip instead of the panel. The panels are steel or aluminum with a factory finish, roll-formed to the length of the roof. The system needs slope, so a dead-flat roof that wants metal usually needs a framed slope or a built-up taper first.

Panel gauge and rib height belong in every proposal. A heavier gauge resists oil-canning and dents under foot traffic, and a taller rib sheds more water in a downpour. The proposal states both, along with the clip type and spacing, so bids are compared on the same footing.

Where standing seam fails first

Failure on standing seam tends to come in four places. Seam ends and laps, where two panels meet along the length. Penetrations, where a pipe, vent or curb cuts the run and the flashing is the only defense. The eave, where ice and meltwater gather in the gutter. And the clips and fasteners that have worked loose or corroded where the finish was scratched.

Civic and institutional buildings are where an owner is likely to weigh metal against a membrane. Staten Island Borough Hall, a 1906 French Renaissance building, stands on Richmond Terrace beside the 1919 Neoclassical Richmond County Courthouse, and the College of Staten Island campus occupies the former Willowbrook State School site.

Condensation looks like a leak and is not one. Warm, moist air meeting a cold metal deck turns to water and drips from the underside, with no breach above. Insulation and ventilation solve it, and a walk that finds the roof dry while the ceiling drips saves a service call to the wrong trade.

What the inspector walks

We walk metal with care, because panels dent and slip underfoot, and we check the seams along their length for opened locks or distortion, the flashings at every penetration, and the eaves and valleys for ponding or rust. We look for scratches in the finish, since bare metal rusts at a scratch, and we count loose or missing fasteners at trim and flashing.

  • Seam locks that have opened or deformed.
  • Penetrations, where sealant cracks first.
  • Trim and edge metal that wind lifts first.
  • Finish, where chalking and rust streaks show worn coating.

Inside, we look at the underside of the deck for staining, condensation and rusted fasteners, which tell us about leaks the surface does not show.

The deck and framing below get a look where we can see them. Purlins that are bent or rusted change the plan, since the clips are only as good as what they fasten into, and a retrofit adds weight the framing must carry.

Repair, restore or replace

If the seams are sound and the damage sits at penetrations or trim, we repair with new flashing and sealant and re-secure loose trim. If the panels are sound but the finish has weathered, a restoration with cleaning and coating can extend life. If seams have deformed along the roof, fasteners have corroded widely or the clips are failing, replacement is the better answer, and we discuss whether to put a retrofit over the existing metal or take it off.

Against a low-slope membrane such as TPO, standing seam lasts longer and sheds snow, but costs more and needs slope. For a truly flat roof, a membrane is the usual choice, and for a pitched roof on a school or civic building, metal is a strong option that we price beside the alternative.

The question of cost comes down to area, gauge, finish, trim, the number of penetrations and the crane. Standing seam costs more than a membrane on a plain flat roof, and less on a large pitched one over the life of the building, which is why the choice depends on the building more than on the product. A short commercial roof repair now can delay replacement for years if the seams are sound.

Ferry-side wind and winter ice

Standing seam is light and sits high, so wind finds it. Sandy's gusts reached 80 mph in October 2012, and roofs near the St. George waterfront and the South Shore take open exposure, so edge metal, ridge cap and eave trim are fastened to the wind rating for the site, and we check that attachment after every big blow.

Snow slides off metal in slabs. New York City gets about 29.8 inches of snow in a typical year and logged 27.3 inches in one day on January 23, 2016, and a slab dropping from a roof edge onto a sidewalk is a hazard, so snow guards belong in the plan above entrances and walkways. Gutters take the ice, and a gutter that has pulled away is a winter finding.

Lifts, schools and warranty

Metal panels are long and awkward. They are lifted by crane or hoist and handled without kinks, so we plan the lift, the staging area and any street closure in advance. On a school roof or a civic building we schedule noisy forming and fastening for off-hours and keep the area below clear.

Finish and weathertightness warranties carry terms set by the panel maker, and installation must follow them for coverage to apply, so a roof warranty management review comes before the order. Owners near St. George can hand us the roof type, slope and leak history.

After the work we photograph every seam end and penetration and record the clip layout, so a later repair starts from a record of how the roof was assembled and where the trim fastens.

Related Roofing Work

More roofing work that comes up alongside Standing Seam Metal Roofing.

Commercial Roofing Questions

Can standing seam go on a flat roof?

Not directly. It needs slope to shed water through its seams. A flat roof that wants metal needs a sloped frame or a tapered build-up first, and many flat buildings are better served by a membrane.

Why does a metal roof leak when the panels look fine?

The water almost always enters at a penetration, a trim piece or a seam end rather than through the panel. Cracked sealant, lifted flashing and loose clips cause most of it, and those are repairs.

Does a metal roof make noise in heat or rain?

Popping in heat or cold is thermal movement, and clips that allow sliding make less of it. Persistent banging points to a loose clip or fastener.

Can metal be coated instead of replaced?

Often, if the panels are sound and the finish has weathered. Rusted or deformed panels need replacement.

Do I need snow guards?

On a pitched roof above a walkway, entrance or loading area, yes. We set them to the snow load and the layout.

Ready to review your roof?